  1. madvb

    Wet-pipe or Dry-pipe system?

    1) What is the proper way to determine whether a dry-pipe or wet-pipe system should be used? I have looked at design winter dry bulb temperatures, and it seems that most cities in California have a winter dry bulb temperature at or below 32°F and record low temperatures even lower. Winter...
  2. madvb

    Dry sprinkler heads in Wet-Pipe sprinkler system

    In areas that don't really freeze (2-3 days out of the year where temperature might drop to 25 deg F), is it possible to use some dry sprinkler heads in a wet-pipe sprinkler system, such as in attic (insulation at ceiling) or under overhangs? Thanks.
  3. madvb

    LPG tank outlet pressure

    Does anyone know what a typical vapor pressure at the outlet of a 500-1000 gallon propane storage tank is....after it has been regulated down? I assume that the propane tank has a pressure regulator on it. I have a 1000-gallon propane tank on site that will feed 3 buildings. Each building...
  4. madvb

    Painting of exposed natural gas/propane pipes

    Hi, I'm looking for the type of prime coat and top coat for painting an above ground exterior black steel used for natural gas or propane. I have used alkyd anticorrosive metal primer and alkyd enamel before, but was told that I cannot use alkyd anymore because the product is not low VOC...
  5. madvb

    Hi-Fog

    Hi, Anyone familiar with or have used the Hi-Fog fire sprinkler system by Marioff? I'm not sure if the system is UL listed or approved by the State Fire Marshal. Wanted to see the advantages/disadvantages of the system.
  6. madvb

    Minimum pressure needed at fire riser...

    Hi, What is a typical pressure loss through a fire sprinkler system for a single story office building (4000 sf) with about 200 feet of piping? We have been doing a deferred approval so that a sprinkler contractor will design the system and get approvals, so I do not know how much loss through...
  7. madvb

    Fire Pump selection for a fire hydrant

    Hi, I'm trying to select a packaged diesel fire pump to provide flow to a hydrant on a site. The facility is connected to the city's fire water line, but does not have enough pressure. If a fire hydrant is required to have 1500 gpm at 20 psig, does one select a pump for 1000 gpm or 1500 gpm...
  8. madvb

    Trench Drains

    Not sure if this question is posted in the right place. Does anyone know if trench drains that are installed inside a building (auto repair shops) require p-traps and vents? This is drained to a sand/oil interceptor located outside the building. I figured the sand/oil interceptor acts like a...
  9. madvb

    Autoshop

    Hi - I'm looking to put a 250-gal waste oil tank and a 250-gal waste antifreeze tank for an autoshop. Can someone suggest a manufacturer? This will be aboveground outdoor installation. Should a single wall or double wall tank be used in this case? I'm thinking of putting a small container...
  10. madvb

    Combined Hydronic Piping

    Hi all, Has anyone done a combined hydronic space heating and domestic hot water piping? I have a boiler that will provide heating to my VAV boxes while running its hot water through a heat exchanger for domestic hot water. I am having a hard time coming up with a schematic diagram that will...
  11. madvb

    UL Design Number and Detail

    Hi all, I'm designing a project that requires fire sprinklers in the building. Since we don't have a specialist in fire sprinkler, I'm just going to do a performance specifications for the fire sprinkler system and have the contractor design/build the fire sprinkler system. The plans and...
  12. madvb

    Non-Freeze Wall Hydrant

    Our winter design condition is 20 degrees F. Does anybody make a concealed non-freeze wall hydrant? J.R. Smith has a non-freeze wall hydrant, but the water pipe is not concealed inside the wall. The pipe is sticking into the room and doesn't look too good. I guess it's probably the only way...
  13. madvb

    Water Distribution

    Can anyone recommend a good program to model a water distribution system? We are using an old version of Pipe-Flo. This old version is really not easy to input, especially when we have a big site with lots of nodes.
  14. madvb

    High pressure (water/steam) engine washer

    Does anyone know where I can find the requirements/codes regarding putting a couple of high pressure (water/steam) engine washers in an autoshop? What would the autoshop need to have in order to accomodate these engine washers?... special drainage system? Thanks in advance.
  15. madvb

    Polyethylene or plastic natural/propane gas line above ground

    Does anyone know if it's a good idea to run polyethylene or plastic gas pipe from under ground and rise above ground to a plug valve before entering a building? NFPA 3.1.7 says that plastic pipe shall be installed outside and under ground only.... with 2 exceptions: 1. Plastic pipe shall be...