  1. DouginMB

    Lab hood control by heat sensor

    I'm in the process of designing the ventilation systems for a lab. A couple of the lab hoods simply vent heat from heat generating equipment. Is anyone aware of a sensor I could use to operate the hoods by detecting the radiant heat from the equipment? I'm assuming I can't use a temerature...
  2. DouginMB

    Steam system inspection tips?

    Next week i am going to a military base to perform field work for a renovation. The building is served by a campus steam system. The base engineer has asked me to inspect the condition of the existing steam and condensate branch pipes to the building and determine their condition. While i have...
  3. DouginMB

    Steam system inspection tips?

    Next week i am going to a military base to perform field work for a renovation. The building is served by a campus steam system. The base engineer has asked me to inspect the condition of the existing steam and condensate branch pipes to the building and determine their condition. While i have...
  4. DouginMB

    Anyone have 98 International Mech. Code?

    I need help with a code question and don't have a copy of this code. I designed a mechanical system in another state based on the 2000 IMC. The 2000 IMC allows you to provide ventilation air based on the actual occupancy of a space rather than the square footage occupancy in the table. The code...
  5. DouginMB

    Bizarre VAV problem

    I am having problems with a VAV terminal box serving a row of offices along the exterior of an office building. The VAV box discharges 83F air. The duct discharges from the box into about a 5 foot run of rectangular duct and into a dovetail wye fitting. The duct then runs each way over the...
  6. DouginMB

    Cooling Coil Fouling

    I am investigating a cooling problem at a local hospital. They have an air handler and associated coil that is about 24 years old. The original specs are as follows: Airflow = 48,000 cfm EAT = 80 degrees F LAT = 50 degrees F Fluid (Water) = 42 degrees F Fluid Flow = 380 gpm The actual...
  7. DouginMB

    KW vs. KVA

    I'm an HVAC engineer and work mostly with KW's when specifiying power loads. I have seen loads referenced in terms of KVA. What is the difference? Is there a simple conversion?
  8. DouginMB

    Chilled/Hot Water Chemical Treatment

    One very weak part of my companies specifications is chilled & hot water chemical water treatment. The main reason for this is that I've never seen a product vendor in the 10 years I've been in the business. Does anybody know who makes these products or where I can find a guide-spec for them?
  9. DouginMB

    Fan Belt Failure Data?

    Does anyone know where you can find information on the failure rate of fan belts for fans that operate continuously?
  10. DouginMB

    IBC and ventilation

    I am facing a frustrating situation and would like some insight from some other folks. Three years ago I designed an HVAC system for a church school. It was a two phase job: classrooms and gymnasium/cafeteria. The first phase was built immediately and the second was deferred until more funds...
  11. DouginMB

    Test Port Valve question

    Are pressure-temperature test valves for HVAC balancing valves a standard size? Or do they vary from manufacturer to manufacturer? The reason I ask is I bought test gages from a manufacturer that sells "green" pumps and tried measuring flow across the triple-duty valve of a company...