Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: 22574
  • Content: Threads
  • Order by date
  1. 22574

    PDC

    A core balance ground ct connection was used in O/L in a Motor, while residual ground CT connection was used for O/C at the secondary side of Transfomer going to the switchgear where the motor connected. My question is, can I coordinate the two relays? What is more sensitive during ground...
  2. 22574

    Generator tubular Busbar

    Hi everyone, Can anyone direct me to supplier for a Generator Tubular Busbar? Thank you.
  3. 22574

    SR469 relay manual

    Does anyone have a copy of manual for SR469 relay?
  4. 22574

    Relay setting

    Can anyone help me how to compute the relay pick up, time delay and instaneous setting, to tell you the truth I dont know how to deal with it. Hope you can help. Thanks. S4-S1-SA, upstream. S4: CT Ratio 1000/5, Full load amps: 710 Amps,SCA-3p: 21,208Amps S1: CT Ratio 2500/5, Full load amps...
  5. 22574

    Transformer testing

    Can you suggest what is more advantage or helpful in Transformer testing, doing insulation resistance test or insulation power factor test. Thank you.
  6. 22574

    LG and LL fault

    Hi, Anyone can provide me some formula or computation why a L-G fault is higher that L-L fault in distribution system mostly with XLPE feeders? Existing Transformers are solidly ground. Thanks
  7. 22574

    Earth fault relay

    Hi Guys, I need a help in looking for a procedure on how to set an earth fault relay What are parameters needed, (eg. short circuit fault, etc..) Thanks.
  8. 22574

    How to test SEL 121G

    Hi All, We have a SEL 121G for lab use, but my problem is I dont how to test it, does anybody have test procedures on this relay using doble f6150?
  9. 22574

    Hydrogen in Transformer Oil

    What is the effect of Hydrogen in tranformer Oil? How hydrogen form inside the transformer? I hope you can help me on this.. pabs
  10. 22574

    wire rope use in KRUPP crane

    Can anyone provide me supplier for the wire rope use in a KRUPP Crane. 80Tons, Capacity with 3/4" dia. I will appreciate your help.
  11. 22574

    Circuit Breaker Testing

    Is there a need to conduct Reduced Voltage Trip and Close Coil Testing on circuit breakers? What maintenance is necessary for tripping and closing coils of circuit breakers? What are their current maintenance practices in trip/close coils? Any IEEE/ASTM Standard related to trip/close coils testing?
  12. 22574

    Inrush current calculation for Capacitor bank

    Does anyone have a formula in calculating the inrush current for Capacitor Bank. The scenario is: there are two Capacitor Banks connected in parrallel, in each bank there is a series damping reactor connected. Thanks.
  13. 22574

    Use of Neutral in a Auto_Transformer

    Any one can explain to me what is the use of Neutral in a autotransfomer? I have an Example: 200MVA,Single-phase Autotransformer with tertiary, Y-connected. 500KV-primary,230kV-secondary and 13.8kV.(a),(b). My another question is: if the neutral-wire going to diverter switch will cut off, happen...
  14. 22574

    Substation Rated Capacity

    If the transformer of a substation had a capacity of 60MVA/80MVA/100MVA; OA/FA1/FA2. Can I say that it is a 100MVA S/S? Could anyone can explain to me if this right or not? Your reply is highly appreciated.
  15. 22574

    Power Transfomer Testing Instruments

    I am looking for a complete Power Transformer testing instruments.. please specify what brand. Eduardo
  16. 22574

    Causes of Bushing Failure manufactured by Haefely Trench

    Could anyone can provide me some of their experience of Transformer Bushing Failures manufatured by Haefely Trench. We are preparing a report regarding our 100MVA Transformer that was totally burnt due to bushing failure recently. eduardo
  17. 22574

    descriptive

    Anyone knows an instrument use to measure actual core loss, copper loss of an existing transformer..
  18. 22574

    I am looking for Daihen Transformer Bushing specs

    Anyone can help me to know the bushing specs(primary & secondary) of this Transformer. Daihen Transfomer, formerly OSAKA Transfomer CO., LTD This transfomer is very old(1976, its manual is lost already. Here is the Transformer nameplate specs. KVA Rating: 67700 Phase: 3 Class: OA Serial #...

Part and Inventory Search