Hello everyone,
I've reading some info about how to pipe size loops herein however it seems that there are no defined rules to do it.
1) some people say the leg of loop should be H=2W, where H is height and w=whith;
2)others say H=W;
3)also each guide near to loop have a distance of W...
Do we really need to construct the nomographs shown in API-650, Appendix P?
CAESAR II gives automatically the allowed radial force, and the allowed circunferencial and longitudinal moments.
So after run the piping flexibility analysis we just need to compare the values above mentioned with...
Hello everyone,
I am currently analysing appendix P of API-650, once I have to calculate the allowable external loads on tank connections. However this API only describe a method to tanks larger than 36 m in diameter.
Please could anyone tell me how should I procede for tanks smaller than 36...
Hello everyone,
I'm modeling a piping system where I have to know the loads on a tank nozzle due to the piping connection.
The model is defined as well as the data for the type of tank and nozzle, so that CAESAR II can give me the maximum allowable loads, stiffness coefficients and its...