Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations MintJulep on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. BS2

    "U" bolt Anchor in Concrete

    Yes, it is for a Missouri DOT project. Here is the overlayed detail: It looks like one of the longitudinal bars will go through the U-bolts. And the #5 stirrups are at 12"oc so the #4 by 18" bars should be encompassed by at least one stirrup. Thanks for the help!
  2. BS2

    "U" bolt Anchor in Concrete

    I am analyzing the anchors for an AASHTO pedestrian fence according to the following detail. This configuration was provided to me and I typically use an alternate anchoring detail. However, for this project, the detail was specified by another engineer and I am tasked with checking it. I...
  3. BS2

    Allow Absurd Load Combination to Control?

    I have run into this scenario several times. In my case, the structure was a decent size - approximately 400'x400' with a very lightweight roof. Applying the roof live load reductions resulted in a 12 psf roof live load. This is approximately 1,920 kips of roof live load. The structure was...
  4. BS2

    Post Tensioned Slab On Grade

    Thanks for the replies thus far. I am not the EOR. I was asked by the contractor about this situation. The owner is willing to accept the opinion and recommendations of a PE. The obvious and default answer is to repair the tendons. However, I wasn't sure if anyone had experience not...
  5. BS2

    Post Tensioned Slab On Grade

    Good point, I should have specified. The tendons are unbonded. The contractor would prefer not to retension if possible.
  6. BS2

    Post Tensioned Slab On Grade

    Background: I have run across an existing building with a post tensioned slab on grade spanning between grade beams and belled piers bearing approximately 10'-12' on bedrock. The building is three stories, approximately 25 years old, is configured in plan view as an "X" shape, and is relatively...
  7. BS2

    OCBF - Allowable Eccentricity

    Thank you all for the replies! JAE - Yes, my initial thought was to keep the eccentricity to a minimum. 6" does not sound unreasonable to me but I want to make sure we are at least meeting the intent of the code. And yes, the rod is through bolted to the face of the HSS4x4x1/4. This does...
  8. BS2

    OCBF - Allowable Eccentricity

    An ordinary concentrically braced frame (OCBF) was designed in SDC D with 1/2" diameter steel rod welded to a plate and bolted to the face of a HSS4x4x1/4. The baseplate is attached to the concrete with 3/4" epoxy anchors. See the picture below for a sketch. The detail shows a 3" offset...
  9. BS2

    Moment Connection to a Knee Brace

    Thanks for the responses! JoshPlum: My question is primarily about whether I can design a moment frame in a high seismic zone with this or a similar configuration. Not shown on this model (but shown on the picture below) are a couple of other longitudinal beams which bear slightly inboard from...
  10. BS2

    Moment Connection to a Knee Brace

    I have a unique framing situation for a mechanical structure designed under Chapter 13 of the ASCE 7-16. The seismic loads are large (SDS = 1.2). The attached RISA output shows one bay of a knee braced frame. This structure supports some equipment. Due to other space constraints not shown...
  11. BS2

    ASCE 7-10 Chapter 13 - Welding

    JAE - Thanks for the reply. That seems to make sense - and I did see that provision but it seemed so generic that I thought there must be some other requirement. In this case, it is mounted to a slab on grade but other times it is mounted to a mezzanine slab.
  12. BS2

    ASCE 7-10 Chapter 13 - Welding

    I have a steel conveyor system designed under ASCE 7-10 Chapter 13 in SDC D. The R is specified per the chapter as R=3. However, I can not find where the weld requirements are specified if there are any. It does not seem to fall under AISC 341 as far as I can tell. I am getting questions in...
  13. BS2

    Hollow Architectural Wood Columns

    The columns are spaced a maximum of 6' apart and some are 3'-4'. I analyzed the beam as light storage as this is a theater and they are currently using it to store some light equipment, supplies, and performance equipment. They may turn it into a seating area and 100 psf would be more...
  14. BS2

    Hollow Architectural Wood Columns

    And a couple more pictures. https://files.engineering.com/getfile.aspx?folder=9f642de0-9622-4f4c-bb57-1c3ef481343f&file=IMG_3697.JPEG https://files.engineering.com/getfile.aspx?folder=b98ac0da-270c-4589-9d77-6f9f36366cc6&file=IMG_3688.JPEG
  15. BS2

    Hollow Architectural Wood Columns

    Column Pictures - The 2x4's inside are just loose and are not present in the installed columns.https://files.engineering.com/getfile.aspx?folder=8eedf8c6-3566-4c2b-a04c-03fd4791908a&file=IMG_3687.JPEG
  16. BS2

    Hollow Architectural Wood Columns

    I have attached some pictures which show the column in greater detail. I have also attached a quick sketch of the column. When I mentioned tapered, they are tapered by approximately 1" over the length of the column. I believe that the individual pieces are relatively straight. I am 100%...
  17. BS2

    Hollow Architectural Wood Columns

    I have come across existing architectural wood columns which are hollow and tapered slightly. They are approximately 9" in diameter and consist of 12 individual "studs" glued together. How would I go about verifying the load bearing capacity? I was thinking that it could be approximated by...
  18. BS2

    Cold Formed Steel Joist to Wide Flange

    cliff234 - I believe the Simpson L70 is both a wood and CFS connector. KootK - Exactly. I figured they could shift the whole line of joists over 8". I am contemplating the idea that the tightened bolts will provide some frictional resistance to torsion even though they are in slotted...
  19. BS2

    Cold Formed Steel Joist to Wide Flange

    Thank you all for the comments. The Simpson L70 is simply a right angle bracket with four screws on each side. KootK - Yes, the original detail required flange coping. And yes, I agree, part of the reason for my concern was the short slots. To add a little bit more detail about this topic...
  20. BS2

    Cold Formed Steel Joist to Wide Flange

    I have a situation where I designed cold formed steel channels to be supported by a wide flange beam on one side only. I specified a Simpson L70 connector in an effort to reduce the amount of torsion induced in the wide flange. The steel shop drawings I received showed a shear tab connection...

Part and Inventory Search