Is there a way using Compress to model/calculate a 'branch' connection? What I have is a 20" liquid outlet out of the bottom head. In the horizontal part of the nozzle after it exits the skirt, there is a smaller 4" branch drain nozzle attached. Any ideas??
Thanks Tom.
I figured that was it, even did that before posting, using the global change to update my external pressure but still got the same error. I just did it again and the error has gone away.
Lesson learned: never under estimate the power of a re-boot.
Thanks again.
I'm getting the following deficience error on my top head of a vertical tower:
* External design pressure varies across this chamber.
Any thoughts as to why?
I am aware and take full advantage of Table 7 when it applies. It works for some of my applications but not all. I will run some number as per you original reply and see what comes up. Thanks.