hi all..
apologize to attach the attachment..
https://files.engineering.com/getfile.aspx?folder=63e74b81-5787-4451-b4a5-7a745f2f61ea&file=acess_stair_on_tank_roof.jpg
hi all..
i have access stair between tank which sit on the tank roof structure (see on the attachment)
The tank diameter is 38 meters, and self supported cone roof tank
tank height is 19.5 meters
Thanks for your advise
regards,
rudiawan
all..
we are using overflow weir box on the water tank (designed follow API 650)
as seen on the attachment, the overflow pie diameter 1s 1200 mm
The boz size is 3m x 3m x 3m
can we evaluate the load on the tank shell that is connected with overflow box using nozzle pro..
peaase advise if other...
all..
we are doing pipe routing for the pipe connect to tank, the data as follows :
- the diameter of pipe connecting to the tank is 1500 mm
- tank diameter 38000 mm
we have performed the pipe stress and get Force and Moment on the tank nozzle
My questions is how to evaluate the force and...
i do the pipe stress analysis for piping connecting to the api 650 tank.
refer to annex P on the API 650, The limiting piping loads are as follows: FR, MC & ML
FR max is the radial thrust applied at the mid-surface of the tank shell at the opening connection, in N (lbf);
MC Max is the...