@pierreick, @MJCronin, @LittleInch thanks a lot.
Our existing cooling tank (conventional) having problem with cooling time for batch process (slurry product)
And we will change into conventional with 2 inch inlet/outlet (bigger then existing) or we have to change into Half pipe coil jacket to...
Dear all,
As far i knew, there are 5 type of reactor jacket:
1. Conventional jackets
2. Half pipe coil jackets or split coil jacket
3. Dimple jackets
4. Constant flux cooling jacket
5. Internal coil
What are the strong & weakness of chemical reactor jackets from above, which one is better in...