    New tank bottom, hydrostatic test?

    Thank you roughandtumble, yes water is the issue, but the requirements that must be met are established in API 653 and they are the appropriate parts of 12.3.2.3 through 12.3.2.6. Paragraph 12.3.2.5 determine conditions for shell-to-bottom weld repair that is not possible meet in this case...
  2. Jaosis

    New tank bottom, hydrostatic test?

    Dear sirs, Is it possible to remove an entire old tank bottom cutting the shell-to-bottom joint and install a new tank bottom without doing a hydrostatic test according requirements of API 653 12.3.2 that states necessary conditions that shall be satisfy in order not to carry out a hydrostatic...