L/480 is an ok starting point but for 29-ft, that is 3/4-in live load of deflection and over 1-in total load deflection. If there is tile, you probably want to go at least L/600 lest the tile crack. Furthermore, if this is over a crawlspace (or another area where there is no directly attached...