  1. smaug6

    HEC-DSS File format

    I am new to HEC and I have created a DSS file for study of a stream near my home. I have input the flow data but cannot get HEC-RAS to read my file. What have I done wrong? http://files.engineering.com/getfile.aspx?folder=0c449274-6c98-4daa-b958-211a1bbec3fb&file=jones_lake.dss...
  2. smaug6

    HEC-HMS Paired Data Entry

    Never mind I deleted 3.4 and 3.3 runs. Thanks again for the assistance.
  3. smaug6

    HEC-HMS Paired Data Entry

    SMIAH, Well I found that button but unfortunately when I use it all data entered into the table instantly and un-explainably disappears??!?! http://files.engineering.com/getfile.aspx?folder=38f5d936-c4c3-48d9-bedc-c1b00b463d3a&file=Prior_to_Apply.jpg...
  4. smaug6

    HEC-HMS Paired Data Entry

    SMIAH Thank you very much! Where is the apply button? It has been a while since I have used the program.
  5. smaug6

    HEC-HMS Paired Data Entry

    In the past when I have used HEC-HMS I have usually manually entered my paired data table data manually. For some reason when I do this the data won't stay in the table. Why is this? I have never had this problem before.
  6. smaug6

    Intermittant distribution system low pressure remediation

    I am analyzing a water system that has intermittent low system pressure. The situation is that this system lies on a lake and experiences periods of very high demand. I am sure the distribution system; which consists of a standpipe elev. 812 ft 37 ft high. and approximately 2.6 miles of unlooped...
  7. smaug6

    5000psi grout as a structural footing?

    Maybe water permeability reduction is the issue the contractor wants to address.
  8. smaug6

    Deflagration vent

    I am using guideline from FM approval standard 6049 for the design of flammable and combustable liquids storage buildings to size vent area. Which NFPA doc are you referring to NFPA 68? BTW, did you understand the venting concept I was referring to in the first post. Using your dimensions and FM...
  9. smaug6

    Deflagration vent

    DEAR IFRs, FM-Factory Mutual, IBC-International Building Code,IFC-International Fire Code. BTW remember you need to design your structure for 100 psf internal pressure. We are a detached flammable and combustable liquids storage building manufacturer and have experience with this application...
  10. smaug6

    Deflagration vent

    FM HAS APPROVED RELIEF WASHERS. USING IBC CODE REQUIREMENTS 1FT2 VENT AREA FOR EVERY 50 FT3 INTERNAL BUILDING VOLUME. RELEASE FORCE OF 20 PSF APPLY APPROPRIATE NUMBER OF WASHERS. APPROVED WASHERS ARE FROM CAMCAR THEY START AT 70 LB PER WASHER. MAKE SURE TO FOLLOW CLEARANCE GUIDELINES FOR SIDE OF...