  1. ximba1

    WaterCad

    Thanks for the replies. CPENG78 Actually the 53 psi is a residual pressure. I have seen engineers doing this (53 psi/0.4333) + finish ground elevation say 60' = 182' and use this as the elevation at the reservoir. IS this correct?
  2. ximba1

    WaterCad

    I am doing a waterCAD design and the county sent me the tie in water pressure = 53 psi First questio - is this correct to converte psi to an elevation at the reservoir (Elevation = 53 psi/0.4333 = 122 ft) so this is the elevation on my reservoir and then i set the elevation at the junctions on...