Chinwar,
Fire-safe testing of ball valves involves two main tests, integral test (to proof the body,trunnion,stem seals) and a function test ( to proof the ability of the valve to close and seal) in the event there is a fire.
The primary seals (elstomers) of the valve can be materials of such...