AF-402 3rd sentence states"The exemptions for post weld heat treatment in Tables AF-402.1 and 402.2 are not permitted when the vessel is designed for lethal service. (AG-01.1(c)...."
However, the Notes of Table AF-402.1 for P1 material (2)(b)1,2,3,4, list conditions where heat treatment is NOT...