apc2kp> You are correct, we have a cooler between the mixer and the tank, cooling the mixture from 58-60°C to 13°C using a brine solution. First we got the two pumps, then the t-junction, a pulsation damper, the cooler and then the tank. We got a nitrogen valve on the tank to apply a pressure...