  1. electrigail

    Unbalanced load/negative sequence currents.

    That's correct that you get eddy currents in the rotor causing heating at twice the machine speed. The negative sequence component is caused by unbalanced loads or faults, and it does flow in the surface iron, slots and rings. High levels can cause failure, lower levels reduce the life due to...