  1. slapjack

    Loadbearing Structural Clay Tile

    I'm doing a lot of renovation work to existing structures built during the early 1900's with loadbearing structural clay tile walls. Anyone know where I can find information on this type of construction that covers: - Example allowable load calculations - Providing new openings with use of...
  2. slapjack

    Cast-in-place Conc + Steel Elevated Parking Structure

    This structure will be located in that Atlanta, Georgia USA area... so there won't be a lot of cold weather like up north. The castellated beams are spanning approximately 60', but deep in size - 30 inches. The 9' spacing just works out with the column grid. I'll do a little research on the...
  3. slapjack

    Cast-in-place Conc + Steel Elevated Parking Structure

    The current design has the slab spanning 9'-0" between composite castellated steel beams. Thanks for all the explanations and recommendations. As far as a sealer/proprietary topping - any suggestions?
  4. slapjack

    Cast-in-place Conc + Steel Elevated Parking Structure

    I have a 2 level elevated steel parking structure with cast-in-place concrete slab on metal form deck. The structure will be open and exposed to environment. AISC Steel Design Guide 18 (Steel Framed Open Deck Parking Structures) recommends the following: 1) Use of normal weight concrete 2)...
  5. slapjack

    What type of steel for an indoor pool???

    On a multi-story hotel with an indoor swimming pool I use steel framing to support the floor above. I usually specify for galvanized steel framing. Just wondering what everyone else uses / recommends - galvanized, stainless, something else? Also, what structural steel members do you specify...
  6. slapjack

    CMU block walls with Hollow Core slab - how high???

    Just curious - how many stories tall have you built using CMU block load bearing walls with a Hollow Core slab system? We are looking at an 8 story hotel and wondering if this type of construction is feasible for such heights.
  7. slapjack

    Hotel Corridor Live Load

    On a typical over-night hotel, rectangular in shape with rooms on each side of the building and a long corridor down the middle, which design load should be used for the corridor? (a) 40 psf - Private rooms and corridors serving them or (b) 100 psf - Public rooms and corridors serving them...
  8. slapjack

    RTU Support/Framing

    When providing structural framing between bar joists for the support of roof top units, how is the metal roof deck cut to provide chase openings... do they cut the metal deck out for the entire perimeter of the RTU curb or do they only cut the deck where the supply and return chases pass through...
  9. slapjack

    Tilt-Up Panel with 2 differing thicknesses

    I've got a situation where the panel thickness needs to be 7.25" from finish floor to roof and 9.25" below finish floor to footing (-4'-8"). The client requires that the dock wall extend 2" beyond the exterior face of the building. Ideally, I would like to have one continuous panel for the...
  10. slapjack

    Masonry Control Joints at Intersection Walls

    Trying to determine which is correct... our general notes read such that a masonry control joint shall be placed at all masonry wall intersections. However, we also show a typical detail for a T-shaped intersection where T-shaped horizontal joint reinforcement is called for to maintain...
  11. slapjack

    Epicore Design Tables

    Starting a new job with Epicore... anyone know where I can find design information (load tables, typical sections, etc) for this product online? I've contacted Epic Metals to request information, but I'm hoping there's something in electronic format (pdf) that I can download and get my hands on...
  12. slapjack

    Frame Sidesway - braced or unbraced?

    I contacted Seth at RAM and all they have to offer is exactly what is printed in the manual. Anyone else have any info or suggestions on where to find more information on this topic?
  13. slapjack

    Frame Sidesway - braced or unbraced?

    I actually do have eccentric braced frames in one direction... concentric in the other. Can you give me a little more information on how I can determine if the frames are considered braced or not based on the displacement? Is there a section of the building code or steel manual that tells how...
  14. slapjack

    Frame Sidesway - braced or unbraced?

    I'm running a computer model of a 5 story office structure (RAM). The lateral force resisting system is made up of 2 L-shaped braced fames located on opposite corners of the structure. Each floor will consist of a 3" concrete slab (rigid). With this configuration, I would assume that I should...