Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. mshani

    Bracing compression chord in a Bridge Truss

    I am working on a truss design for Highway bridge. I needed some help in lateral bracing of the compression chord. AASHTO 6.7.5.4 Trusses states "the member providing lateral bracing to compression chords should be as deep as practical and connected to both flanges." Can I use W12 member aligned...
  2. mshani

    seismic for multi-span bridges

    crossframe... thank you for the explaination. "Simple span bridges do not have a "structure response" because there is nothing else to give the bridge a different period (like a column). " Keeping this in mind, if in multispan bridges we releasae the movement in longitudinal direction for the...
  3. mshani

    seismic for multi-span bridges

    Yes we do have to do a multi-modal analysis. However for preliminary analysis we are using uniform load method. Can anybody explain me the reason why we are not required to do any seismic analysis for single span bridge? AASHTO only requires to provide connection of superstructure to the...
  4. mshani

    seismic for multi-span bridges

    SEISMIC ZONE 3. Are you saying that we should design the abutment and piles for the lateral load even for single span bridge? If yes, how do I find the lateral load on the abutment when it clearly says no seismic analysis required? Please bare in mind that i am not asking this question with...
  5. mshani

    seismic for multi-span bridges

    I am designing a multi-span steel composite beam with concrete deck. I have few questions on seismic design of piers/abutments in multi-span bridges. Below is the bridge restraint information Single-span *End abutment 1 Free in longitudinal direction Restrained...
  6. mshani

    MIDAS CIVIL

    I am looking into different softwares for bridge design. Has anybody used MIDAS Civil for bridge design, especially suspension bridges?
  7. mshani

    Premature refusal

    Thanks BigH. What is the main cause for this behavior?
  8. mshani

    Premature refusal

    What is "premature refusal" for driven piles?
  9. mshani

    Historical shape

    Seems unlikely. The date on the drawings is 1928. The architectural section does not reveal anything (as usual). The building framing system is steel columns and beams and conrete pan joists for floor framing.
  10. mshani

    Historical shape

    Does anybody know what does 6-H-24.1 stand for? I am checking capacity of an existing structure and came across this beam call-out which I could not find in the historical shapes excel sheet in AISC. Thanks
  11. mshani

    Opening file

    I tried to analyze 7.24 version file in 9.0.4 and it gives me Analysis incomplete Due to error COULD NOT ALLOCATE ARRAY NAME = Coor_rXyzALL ALLOCATE ERROR # 165 Any idea what can I do?
  12. mshani

    Shearwall Modeling Technique

    I have a 26 story building in seismic zone 3. The main lateral system consist of 46'x46' interior concrete core with additional perimeter frame for 25% EQ loads. When I am modeling my shear walls with 4 corner supports, I am getting huge lateral forces even in DL or LL cases. Overall lateral...
  13. mshani

    Seismic Connections - Concrete filled steel tube

    Can anyone provide references on seismic connections of steel beams to concrete filled steel tubes? In particular "J-Bolt" type connections. Thanks
  14. mshani

    EARTHQUAK LOADS UBC 97

    Algorithm for 1997 UBC Seismic loads is based on Chapter 16, Section 1630.2 in ETABS. I was wondering if one has to check for loads based on Seciton 1630.1?
  15. mshani

    Edge Column Moments

    When designing flat slab with SAFE, I am getting high unbalanced moment on exterior columns (with edge beams). Should column design, which typically includes only gravity loading, include this unbalanced moment? Please share ur views..
  16. mshani

    MASONRY UNIT MANUFACTURERS

    I need concrete masonry manufacturer info who can make units with 5250 psi net area compressive strength. Thanks
  17. mshani

    ETABS FLOOR ASSIGNMENT

    Will assigning it shell lead to high out-of-plane bending of the slab and hence reduction of total lateral deflection at top? I tried to model a typ. bldg. with both ways only for lateral loading. Results showed increase in deflection when slabs assigned membrane rather than shells. Have u...
  18. mshani

    ETABS FLOOR ASSIGNMENT

    How should I define conc. slabs in Etabs, Shell or Membrane, especially if I want to use same model for lateral as well as gravity load cases?

Part and Inventory Search