Both standards specifies general tolerances for linear dimensions, when they are not explicitly stated on technical drawings. As you see there is no tolerance on 53,9 dimension. So in that case we have to take this tolerance from one of those two norms. But:
- it is a cast part, and it's define...
Hi everyone,
I have a drawing of a cast plate, and on this drawings there is a dimension for both cast and machined features. I want measure this 53,9 distance from a cast hole to a machined face. Should I add tolerances CT9 (±1) from ISO 8062 and from ISO 2768mK (±0,3), or just stick to CT9?