Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations The Obturator on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. driquer1274

    Enclosing a Car Porch with CMU walls

    I will look into wood walls more closely. Thanks.
  2. driquer1274

    Enclosing a Car Porch with CMU walls

    Thanks for the replies. The location is south Florida. Freeze and frost heave are not a concern at all, but wind is. With strong wind loads CMU is usually the most common to resist overturning and uplift. The problem with wood is the existing foundation is not very deep. It is 12 inch x 10 inch...
  3. driquer1274

    Enclosing a Car Porch with CMU walls

    Ron247, There is an existing monolithic slab/footing with rebar reinforcement, and the plan is to raise the existing slab 4 inches to meet the house slab height and be compliant for an enclosed habitable room. Thanks on the load path comment. The overall resistance should be very similar as...
  4. driquer1274

    Enclosing a Car Porch with CMU walls

    JAE, Thanks for your reply. The existing carport does have a monolithic slab poured already which is why I was considering the second option, no vertical load or lateral bracing, but thinking about it more, having a cantilever wall is probably not the most economic way to go about this as the...
  5. driquer1274

    Enclosing a Car Porch with CMU walls

    Hi, I was looking for some advice on enclosing an existing residential car port sharing 2 existing CMU walls with the single family dwelling. The house has a gable roof that extends past the exterior wall and over the car port and is supported by 2 CMU columns on a corner and side of the...