okay guys thanks I knew I had over looked or miss understood something
3.24 Work necessary to maintain or restore a tank to a condition suitable for safe operation. Repairs include both major
repairs (see 3.18) and repairs that are not major repairs. Examples of repairs include:
When it says...
Just playing around and looking at api.org and this question I ran across thought it was not right.
Correct Answer: 4
F. Partial or complete jacking of a tank shell is considered:
1. routine maintenance.
2. a minor alteration.
3. a minor repair.
4. a major repair.
Maybe I am not reading this...
Thanks for the insight and I am going to take a prep class as well I just been studying hardcore and with the prep class everything will come together. But is the closed book only 653?
Going to take my API 653 test, any testing tips been study for 6 months now mostly 653 not the other codes.
1. When you take the close book part of the test is it only over API 653 or it is over 650 651 652 571 etc... I know most likely the open book would be with all the codes. Any advise and...
Studying for API653 in March been studying for a few months I was able to get study guide for it and running across a problem with Plumbness and Tolerances see example problem below.
A reconstructed tank with a diameter of 100 feet and a height of 40 feet is check for plumbness a bob is...