  1. lctommyboy

    Vent size requirement to avoid vacuum in tank.

    One more clarification which may effect the results are that the chilled water is being sprayed into the tank and then draining out a 2.5 inch port. It isn't actually building volume in the tank as it is sprayed in. Would this be considered the same senario as if a heated tank suddenly...
  2. lctommyboy

    Vent size requirement to avoid vacuum in tank.

    Montemayer, The pre-chilled water introduction senario is a residual humid air environment after 160 degree liquid contents has been dumped. Not actually steam-like. If I understand you correctly, the venting requirements established for the volume displacement of the chilled water will be...
  3. lctommyboy

    Vent size requirement to avoid vacuum in tank.

    How do I determine an appropriate vent size to alleviate the vacuum effects for the following senario: 60 inch diameter, 144 inch long horizontal 10 Ga 304 SST tank with flanged and dished heads at both ends which is empty but at a temperature of 160 degrees F with 50 degree water being sprayed...