I suposse that this compression is in a first stage of compresion, because a separator is upstream of suction scrubber. If that's true, in most cases condensation of water and hydrocarbon liquids happens because liquid carryover from the upstream separator or liquid condensation in the piping...
check the following
LEES. Loss Prevention in the Process Industries. Volume I
Radiation and Dispersion Analysis
Is the best compendium..... i was calculated the same but in an offshore facilities and i found the solution in this book
regards
Hi
A dynamic simulation is a simulation doing after a steady state simulation has been solved. In that type of simulation you assess the variables behaviour when a disturbance is applied on a input variable. Additionally, you can simulate control loops. ASPEN PLUS is only capable for steady...
Hi MHodges
a good way is this book
Seider, Seader y Lewin. Product and Process Design Principles. J Wiley. 2004
with a CD with tutorials of hysys ans aspen plus
contact me for that or for training material of aspentech
Hi
Here the cost index of Chemical Engineering, Marshall&Swift, Nelson&Farra and Engineering News Records
Year ChemEng Marshall Nelson ENR
1990 358 935 1226 441
1991 361 952 1253 450
1992 358 960 1277 464
1993 359 975 1311 485
1994 368 1000 1350 503
1995 381 1037 1392...