Problem is that I don't have data for ground temperatures. The installation in question is owned by a water company over 200 miles away so throwing a logger into the installation isn't really practical. A test rig is being set up with an industrial freezer to gain experimental results so...
Yeah that's the right layout and I think you are right that I need more information. It might be the case that some experimentation is needed to figure it out. Thanks for your help
Thanks for the reply.
I already have a calculation for the water going to the pressure transducer to freeze but the calculation is dependent on the temperature of the air inside the chamber. I'm just trying to get an idea of how long it would take for the air inside the chamber to reach the...
Hi guys.