Thank you pvrerate for your reply. We are running Caesar for the pipe analysis and running Algor FEA for a local vessel wall analysis at the nozzle. We are using WRC 297 for the stiffness at that nozzle node in the Caesar model. When running the FEA, we get about .15" deformation in the wall...