  1. 300redbeard

    Flexible Diaphragm for Sun Shade Shelter

    The flat roof is 20'x40' and the hip design is 15'x30'
  2. 300redbeard

    Flexible Diaphragm for Sun Shade Shelter

    I have a background in designing PEB's and mini storage light gauge steel structures. In my experience I have used either diagonal rods or diagonal flat strap bracing for my flexible diaphragms when using steel roof decking that is NOT shear rated: typical standing seam roof. I'm reviewing...
  3. 300redbeard

    Machine Bolts vs. Grade A307

    Thank you all for your help.
  4. 300redbeard

    Machine Bolts vs. Grade A307

    I know machine bolts come in various grades. On construction documents should 'machine bolts' call outs be referenced to comply with ASTM A307?
  5. 300redbeard

    Dowels from CMU wall to slab

    The structure has both 8" & 12" cmu block (2000psi) x 24 to 34 feet high. Footing is 24" & 30" wide x 16" deep. Adjacent mat slab is 8" or 18" thick with #5 @ 12" OC or #3 bars @ 16" OC ea way top & btm. Seismic design category 'D'. My thoughts are that the dowels are for out of plane forces...
  6. 300redbeard

    Dowels from CMU wall to slab

    I'll have to contact the EOR, the calculations are not addressing the dowels. Thanks for the remarks.
  7. 300redbeard

    Dowels from CMU wall to slab

    I'm performing a plan review. Example: 8" slab w/#3 bars @ 18" oc ea way & #4 dowels (from CMU wall) @ 24" oc. (obviously different spacing) Does this fly? I've typically always required/designed my slab steel and dowels to the same spacing for lapping together. I've always had the...
  8. 300redbeard

    Maximum Diaphragm Dimension

    I'd like to thank everyone who gave input. It's pretty amazing in the engineering field how many factors are involved in proper engineering design. I learned something and am grateful and appreciate your helping me to grow. Jon
  9. 300redbeard

    Maximum Diaphragm Dimension

    msquared48, Thanks for the input! The structure is similar to a Super WalMart in design, except reinforcedd concrete walls instead of CMU walls. Your comment: "That's a new one on me. I would never do it. It would drive up the required lateral force significantly." Are you saying you would...
  10. 300redbeard

    Maximum Diaphragm Dimension

    This site is in Calif. site class 'D'. Temperatures range from freezing to 120 degrees fahrenheit. I'm performing a plan check review. I've used cross bracing as well as standard steel decking with diaphragm capacities. My original concern is that the columns, which are spaced at 50 ft OC each...
  11. 300redbeard

    Maximum Diaphragm Dimension

    What section is the 3.5:1 maximum diaphragm ratio as allowed by the IBC under?
  12. 300redbeard

    Maximum Diaphragm Dimension

    In regards to expansion joints, when is a building to large? This structure is 350' x 397'.
  13. 300redbeard

    Maximum Diaphragm Dimension

    IBC 2006 section 2305.2.3 gives ratios for maximum diaphragm dimensions for wooden structures. Is there a maximum diaphragm dimension for a roof diaphragm with VERCO steel deck attached to reinforced concrete shear walls? Thanks
  14. 300redbeard

    Anchor bolt diameter?

    "In general direct shear is not the correct method assumed for shear transfer in base plates" - jsdpe25684 What is the determining factor as to whether you should use direct shear for base plates or not?
  15. 300redbeard

    Anchor bolt diameter?

    Thanks Gentlemen! Advice is appreciated.
  16. 300redbeard

    Anchor bolt diameter?

    I understand the desire for oversized bolt holes for ease of construction, but where do we draw the line? Isn't that what the tables in the AISC and the RCSC are for? I know on School projects in CA they won't accept anything over 1/16".
  17. 300redbeard

    Anchor bolt diameter?

    Public Works Issue-21' tall abutment with 26' span I have an issue regarding anchor bolt diameters. AISC table J3.3 states for 1/2" dia. holes: std-9/16", oversize-5/8" and long slot- 9/16"x1 1/4" respectively. I have a bearing plate on a pedestrian bridge that the fixed end has 3/4" dia...
  18. 300redbeard

    Modular Building Seismic Design

    Thanks for previous responses. Would story drift apply as well? If so, the restraint would have to limit the actual story drift to be less than actual.
  19. 300redbeard

    Modular Building Seismic Design

    If a modular building (trailer) is on 3 ft piers/jacks, should the base shear (at floor level) be multiplied by the pier height for an applied moment to be restrained by seismic holdowns? I've been reviewing calculations from multiple engineers/companies and they are not accounting for the pier...
  20. 300redbeard

    Earthquake Restraint Bracing System

    JAE, That's exactly what I was asking for, and exactly what I thought. Thanks for the reassurance.