  1. Fenixseravgon

    Flow measure of raw material in a continuous online process

    Dear all I'm part of a team working to convert a batch process into an online and continuous process. Please could you give me some ideas of instrumentation to measure the weight of the raw materials (Dust or granulates ) to feed in the process? We are trying to change the way we weigh this raw...
  2. Fenixseravgon

    CHlorination on a line piping

    Ok Thank you I want to clhorinate at 1.2 ppm, 40 cubic meter of water, but i want to add chlorine in the piping after the pump that is going to send the water to the tank instead of install another line of chlorine to the top of the tank and feed in the surface of water. Regrads
  3. Fenixseravgon

    Chllorination on piping line

    Do you think it could be necessary to use a Venturi tube or feeder, the problem is that i'm going to use a Pump and put the feed after the pump to improve the mixing.
  4. Fenixseravgon

    CHlorination on a line piping

    Hi everybody, could you please tell me if is possible to feed sodium hypochlorite on a piping line to chlorinate and mix before send this water to another tank, what tool or technology should i use? Best regards Sergio Avila
  5. Fenixseravgon

    Chllorination on piping line

    Hi everybody, could you please tell me if is possible to feed sodium hypochlorite on a piping line to chlorinate and mix before send this water to another tank, what tool or technology should i use? Best regards Sergio Avila
  6. Fenixseravgon

    Heating load temperature

    Dear All A cleinte give me a temperature for calaculation of the heating load less than the temperature for the cooling load, what should i do to use the recirculation load or use the cooling load to calculate the flow in the AHU? Thanks in advance Sergio Avila
  7. Fenixseravgon

    HEPA Filter integrity test by particle counter

    Hi to everybody It is possible to justify the evaluation of HEPA filter's integrity using a san f the Filter by a particle counter instead of the procedure by ISO 14644-3? Thanks in advance Sergio Avila
  8. Fenixseravgon

    Negative pressure in Room and air balance

    I have a doubt: If a have a negative pressure in a room, does it suppose that i have a negative air change? Because my extraction is bigger than my inyection of air to the room. these is rigth or not? I have to report my air changes in a pharma instalation and i have that doubt. Please help...
  9. Fenixseravgon

    API solubility

    I think you shoud see the merck index and after that the Florey.
  10. Fenixseravgon

    Dust collection system

    Hi everibody I want to know if there is a recommended practice to choose the air filter efficiency for a dust collector in a pharma facility of solids?, It is not a potent active facility, just commun API. Thanks a lot. Sergio Avila
  11. Fenixseravgon

    Dust collector system in a pharmaceutical facility

    Hi Everybody Could you help me?, i need to know the recommended air eficiency of filters for a dust collection system in a pharmaceutical facility. Is there a standad or a recommended practice? Thanks a lot. Sergio Avila
  12. Fenixseravgon

    Process Capability

    Is it Correct to calculate six sigma parameters in process that are controled by a PLC. Example i use an Oven where i steriliza ampoules, i read with dataloggers the temperature inside oven´s chamber. Must i calculate the Cp, Cpk and others measures of capability process?
  13. Fenixseravgon

    VHP change of Concentration

    We have a VHP Isolator, where we use a HP 31%, but in the market there is no more HP of that concentration, only 35%. Must we califiate again the process with this new HP concentration? Must we change the recipe´s parameters? Thanks in advance. Sergio Ávila
  14. Fenixseravgon

    Pharmaceutical HVAC

    Do you know a good book or link about Pharmaceutical HVAC? Thanks in advance. Sergio Ávila
  15. Fenixseravgon

    Negative exponential distribution

    Hi everybody Someone know how to use a negative exponential distribution as a function to have control limits?, or know a good article or url about this distribution? Thanks in advance. Sergio Ávila
  16. Fenixseravgon

    Change of HEPA Filters

    I´m evaluating a electrical oven with HEPA filters to depirogenizate ampoules ina pharma facilities.
  17. Fenixseravgon

    Change of HEPA filters

    Hi Is it true that we muss change HEPA filters if there is a change of 10% in the pressure? it means the filters is satured with dust? Which standar gives that infomation? Thanks a lot Sergio Ávila
  18. Fenixseravgon

    Change of HEPA Filters

    Is it true we muss change HEPA filter if there is a change in the pressure of the filter of 10%? Which standar have the information about that? Thanks a lot? Sergio
  19. Fenixseravgon

    Pages to show my resume

    I´m Méxican, but i want to inmigrate to Canada, What pages for a job seeking do you recommend to me. I´n Pharmaceutical Engenier and have 5 years of experience in contamination control and critical systems. Thanks
  20. Fenixseravgon

    new facility master validation plan

    I read all the messages and i think the same it is a big challenge that you face, but i think the next page can help you a lot: http://www.picscheme.org/, and http://www.ivthome.com/ just keep it easy I hope you may do it all right. Fenixseravgon