  1. yinthenovice

    How to Calculate motor KW given actual RPM , Voltage and Frequency

    aaahhh , the fog of ignorance begins to lift... you see I'm using a 3450 RPM rated motor, and I'm varying it from 300RPM up to 2000RPM. so I'm on the left side of that graph's peak while you were on the right. I was out of the range of 'normal operation'. Which would explain why things are all...
  2. yinthenovice

    How to Calculate motor KW given actual RPM , Voltage and Frequency

    sorry , here's the image http://files.engineering.com/getfile.aspx?folder=94713703-d895-4787-b530-ad13a7848ea8&file=graphics1.pnghttp://files.engineering.com/getfile.aspx?folder=94713703-d895-4787-b530-ad13a7848ea8&file=graphics1.png
  3. yinthenovice

    How to Calculate motor KW given actual RPM , Voltage and Frequency

    jraef: I was hoping to get power delivered , and I just needed a ballpark number. Since this is a one off thing , I had hoped not to pick up a multimeter with power factor. Also efficiency is just a guess at best. I did plug my power supply into a scope and according to my labview software its...
  4. yinthenovice

    How to Calculate motor KW given actual RPM , Voltage and Frequency

    Hi Guys, I have set up a test rig in which I use a power supply to vary the Voltage and Frequency to a 3.73KW AC motor. I am also able to measure the shaft RPM using a tachometer. I just need to know of a way to calculate the power based on this info. Background: I just needed to get the...
  5. yinthenovice

    Store last 50 samples of signal in SIMULINK

    hmm , i'm afraid i couldn't figure that out , I've played around with it a little but no luck . if push comes to shove you can always contact the mathworks support team .... answers seem to be few and far between in this simulink forum for some reason :(
  6. yinthenovice

    Store last 50 samples of signal in SIMULINK

    Okay , i assume you're already aqcuiring this signal okay. So I'd go to the library browser , under simulink\sinks you will find the "to workspace block". Wire your signal to this block . Change block settings to output a vector. The block stores this vector in the workspace called simout (you...
  7. yinthenovice

    What is effect of mismatched op-amp power supply on output error?

    I love this forum , you guys are amazing... In case anyone is intersted , this is what I ended up doing : I just stayed with the power supply i had in the mean time , then i calibrated the amplifier using a much more accurate digital multimeter than I'll be using for the application. So pretty...
  8. yinthenovice

    What is effect of mismatched op-amp power supply on output error?

    thanks for the info , its for a DC signal i'm trying to amplify coming from a shunt resistor. I guess sometimes you want to pull your hair out when you can't explain away that extra bit of noise, especially if you're mechanical trying to learn this stuff . I also think , after looking at Power...
  9. yinthenovice

    What is effect of mismatched op-amp power supply on output error?

    I am trying to amplify a signal from in the range of (0.5mV-5mV) by a factor of 10 using TL082 op amp with non-inverting configuration for instrumentation but my power supply is not exactly the same . I.e +15.3V and -14.8V instead of +/- 15V. When i used Multisim it told me this would make a...
  10. yinthenovice

    Data Center Ultra- Sonic Humidification Retrofit

    KiWiMAce The LPS is in air handler plenum , introducing steam into the supply air duct . Just thinking of taking the whole system out and replacing it. Oh , the Lieberts are not in the same space as the LPS , I kinda forgot about that , they are in their own room . Good link by the way.
  11. yinthenovice

    Data Center Ultra- Sonic Humidification Retrofit

    I'm involved in a project to expand the humidification in a data center , currently using low pressure steam from a pair of 102hp gas boilers. I was thinking of recommending Ultrasonic humidifiers for the new ones and even replacing the whole thing with just ultrasonic , because the existing...
  12. yinthenovice

    Outside Air Damper Leakage Solutions

    thanks guys , i think will go ahead and grab those dampers
  13. yinthenovice

    Retrofitting Demand Control Volume (CO2 Based) to office Building

    hey guys , thanks for the helpful tips . Willard & Cpthk , your experience is amazing and i'm even moe encouraged because the guys who do maintanance on this building also maintain an attached data center , so are dilligent by nature , maintance will be done on time. ChasBean , you ARE the man...
  14. yinthenovice

    Outside Air Damper Leakage Solutions

    I have some really old outside air dampers in office buildings . Maybe 15% leakge or so when fully closed. I'm looking to go to low-leak dampers or else just go cheap and add some blade and edge seals on the current ones. My question is this , has anyone out there had any experience with...
  15. yinthenovice

    Retrofitting Demand Control Volume (CO2 Based) to office Building

    Okay guys , I've been looking at this option for a 13 story office building in the Midwest .The current system is VAV , with VFD (VSD's on all air handlers) , also use some economizer , but minimum outside air on some floors is set for max load , when floors are currently only 30%- 40% full...