  1. szleok

    What load combination used for pile uplift capacity check?

    Thanks. But load combo in 1605.3.2 requires 1.0D+1.3W. That's almost same as 0.6D+1.0W in 1605.3.1 if testing the uplift capacity. I am a little confused here.
  2. szleok

    How to consider wind load on interior component of truss tower?

    But for me, the method 1 seems too conservative.
  3. szleok

    How to consider wind load on interior component of truss tower?

    When I am reading the Figure 6-23 in ASCE7-05, I found something unclear. I have a square trussed tower with 6 columns. There is an elevator shaft inside the tower. The shaft is enclosed but the truss tower is an open structure. As "Guide to the use of wind load provision of ASCE7-02" says...
  4. szleok

    OPEN STRUCTURE WIND FORCE ON DIAGONAL DIRECTION

    But the "guideline for wind load of ASCE" says you only need to apply to the front face of the truss tower.Only 2 columns needs to be assigned.
  5. szleok

    OPEN STRUCTURE WIND FORCE ON DIAGONAL DIRECTION

    My question was: how to calculate the diagonal wind force on open structure?
  6. szleok

    OPEN STRUCTURE WIND FORCE ON DIAGONAL DIRECTION

    ASCE figure 6-23 has Cf factor calculation for open trussed tower. Does anybody know how to calculate the wind force if the wind blows from other direction? Say, digonal direction. ASCE says to use 75% wind force simultaneously on both orthogonal directions. That's true for enclosed building...
  7. szleok

    What load combination used for pile uplift capacity check?

    In IBC2003 or newer, there are load combinations: 0.6D+1.0W and 0.6D+0.7H to account the safety factor. 1.5 for wind and 1.0 for seismic. But I remember in UBC97, there is no 0.6D in the combination. The 1.5 safety factor is specified in other chapters such as retaining wall, spread footing...
  8. szleok

    Inter-story drift ratio Vs. overall story drift ratio

    As we al know, the inter-story drift ratio is an important coefficient in the high-rise building design. However, is the Maximum displacement / building height considered as a more important index in US design? Say, satisfy the wind load to 1/400 x H.
  9. szleok

    Shell force output

    THe contour is interpolated by the joint forces. Not real calculated value. So if you want to see the detail force in a single element, you should use finer mesh.
  10. szleok

    SSI

    I would also like to know the new feature of soil-structure interaction function in new SAP. However, as far as I know, SAP don't have sub-structure modeling function and I am wondering the new feature will put the soil perperties into the structure matrix (single matrix). Because in Abaqus...
  11. szleok

    Question on cable

    Hi, all I have question on the cable force. I first applied a negative temperature on the cables to produce post -tension stress in cable. The cable is along a simple supported beam. They have same property. Once the model runned, the cable force will change to different values. The one...
  12. szleok

    How to assign prestress force to cable in SAP2K?

    Anybody has idea to assign prestress force to cable element in SAP2000 v9? I tried to add a load on the axial direction of cable to simulate prestress but I am not sure of this method.
  13. szleok

    Help!!! The correct way to apply acceleration

    Hi, folks I have been puzzled by this problem for a long time: Which way is right? 1. Apply the acceleration on a group of nodes only. *nset, nset=inputnode 1,2,3,4,5 *boundary, type=acceleration,amplitude=?? inputnode,1,1,9.81 2. Apply the...
  14. szleok

    Is the material must be purely elastic in Explicit analysis?

    I have a user defined material which is non-linear. But the Abaqus Explicit can't process it saying the material is not elastic. Anyone has such experience?
  15. szleok

    How to use revise *CONTROLS command according to msg file?

    I got problem on convergency Here is my msg file: EQUILIBRIUM ITERATION 9 AVERAGE FORCE 2.032E+03 TIME AVG. FORCE 993. LARGEST RESIDUAL FORCE -5.84 AT NODE 95 DOF 1 INSTANCE: SOIL-1...
  16. szleok

    Is there any other famous forum for Abaqus modeling?

    Which one is most famous in USA?
  17. szleok

    How to define loading/wave in any direction?

    The UCS has 3 directions and the loading or wave seem to follow those directions. Is there any way to define in any inclined direction? Anyone has idea how to input or modify such direction property?
  18. szleok

    How to define stress time history instead of acceleration time history