Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: mvp23
  • Order by date
  1. mvp23

    Tie Constraint for Welded Edges

    Thanks a lot.
  2. mvp23

    Tie Constraint for Welded Edges

    Any suggestions ?
  3. mvp23

    Tie Constraint for Welded Edges

    Hello, I was wondering if it is possible to apply a tie constraint in a particular step in Abaqus ( while running a multi step analysis). My simulation is a 3 step process. The first step involves the assembly of 2 concentric cylinders, by making a plug move through the inner tube, expanding...
  4. mvp23

    Abaqus explicit - tube drawing model

    ...My end goal is to obtain the residual stresses post assembly. Any help or suggestions would be appreciated. Thanks ....................... *Heading ** Job name: Job-3 Model name: Axisymmetric-Explicit-Copy ** Generated by: Abaqus/CAE 6.12-2 *Preprint, echo=NO, model=NO, history=NO...
  5. mvp23

    Nonlinear Resudial Stresses

    Ok I faced a similar issue a while back where I had to input residual stresses from a static analysis into a fully coupled thermal stress model. I figured that there isn't a way to specify initial residual stresses in Abaqus withouyt using the subroutine. this is what i did Step1 : Fully...
  6. mvp23

    What is the default initial temperature used by Abaqus

    What is the reference temperature used by Abaqus in the event that an initial temperature isn't specified by the user ? My guess is that it uses 0 C or 273 K, but I would like to reconfirm the same. Thanks
  7. mvp23

    Residual stresses using thermal expansion

    settler - i haven't had the need to model a physical fluid cavity at any point. but i looked around online and one post had suggested that if it is required to have a fluid then you would probably have to run a co-simulation of abaqus explicit and CFD. i had suggested a box ( ie a closed region)...
  8. mvp23

    Initial stress imported from .odb file

    Dnov - I'm just curious how to 'request' a restart file. My analysis bails out as it cannot find the *.res file. Your reply could be very helpful.
  9. mvp23

    stress analysis followed by coupled temp disp

    hello, my goal is to perform a static analysis on a 3 cylinder composite by applying an internal pressure on the inner cylinder to begin with. this would be to assemble the cylinders by bringing them in contact. once this is done i would like to perform a fully coupled temp disp analysis where...
  10. mvp23

    Residual stresses using thermal expansion

    create a box or cylinder that contains your liq. i would use a box as you dont have to deal with cylindrical coordinates. i will leave it to you as how to how design this box based on your problem. create a horizontal partition to separate the liquid nitrogen region from the other region. you...
  11. mvp23

    Non-uniform heat generation

    I would like to know if there is a way to output the heat generation rate (W/m^3) in the Abaqus odb.I have a curved beam to which a non-uniform heat generation is applied. Qgeneration = f(thickness,length) I would like to get an output of the applied heat generation to the curved beam just to...
  12. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    Thanks for your help. Under normal behavior , I had unchecked the 'allow separation after contact ' box. That was causing a negative contact pressure.
  13. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    Thought I'll attach a separate plot of COPEN .http://files.engineering.com/getfile.aspx?folder=0ee50de8-88af-4b6e-9586-f77e6a064d23&file=COPEN_plot.jpg
  14. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    ...this with a middle tube being a perfect cylinder. Also , I have this file attached that talks about the subroutine DLOAD and states that " *DLOAD defines pressure (i.e. compressive normal stress) to be positive, so we apply tensile loading by making the pressure negative." Does this...
  15. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    and here is the COPEN plot . Thankshttp://files.engineering.com/getfile.aspx?folder=22e330c1-611f-4cdf-b1bd-e2bc13a4a70a&file=COPEN_plot.jpg
  16. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    I did plot COPEN for the outer tube and my COPEN values are of the order of 8e-10 meters and corresponding contact pressures of the order of -3E06Pa . In another model when I had a separation of 4e-06 meters I got a zero contact pressure. Is this because , the value 2e-11 meters is so small...
  17. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    I can relate to what you are saying. So does open up , the contact pressure on the slave surface will be zero since no contact is being made. Is that right ? I'm seeing contact pressures of the order of -4E06 Pa to -2E09 Pa Thanks for your help.
  18. mvp23

    Negative contact pressures. CPRESS negative in tension ?

    Hi, I have a working model of 3 concentric cylinders with the cylinder in the middle being the master surface and the other two being the slave surfaces. I have a pic attached of the model , which would better represent my question. A gap opens up between the middle cylinder and the outer...
  19. mvp23

    Symmetric model generation / results transfer

    The analysis user's manual section 7.8.1 states that the *SYMMETRIC MODEL GENERATION option is not available for models defined in terms of an assembly of part instances. I guess you cannot use it when you have an assembly of instances.
  20. mvp23

    sequentially coupled analysis

    Yeah I did the 2D axisymmetric analysis and was looking to do a symmetric model generation to convert it to 3D , but the user's manual states that the symmetric model generation cannot be used for models defined in terms of an assembly of part instances. So I guess this option is ruled out ?