vid071892:
Using Denial’s steps I have made Excel spreadsheet – see attachment. It seems to work like a charm :-). Feel free to modify it accordingly. Additional calcs need to be added to keep X and Y scales equal.
As Denial pointed out it was “an interesting little problem”.
Regards,
IV...
...and "haggis" came up with C4x5.4 spanning 9 ft. Is this correct approach? For 9 ft span and 5,000 lbs at middle I am getting C8x18.75 (Mmax=5*9/4=11.25 ft-kips, bending stress fb=11.25*12/11.00=12.27 ksi, allowable bending stress Fb=13.68 ksi for unbraced length Lb=9ft).
Other question: I...
Thank you all for valuable comments.
According to AISC 341-05 Commentary C11.1 OMF Knee-Brace Systems – I can design tower framing in one direction as ordinary moment frames with R=3.5. How about other direction? Any suggestions?
I am doing ASCE 7-05 seismic calculations of cooling tower support steel structure (see attachment) and I am not sure what seismic force-resisting system it is. Ordinary steel concentrically braced frame (R=3.25) or Special steel concentrically braced frame (R=6) or Steel system not specifically...
Our mechanical engineer is asking me to check circular plate made of quartz. Plate is about 14” dia and 2” thick with a lot (about 150) holes 3/16” dia. All quartz properties (E, yield, allowable tensile stress, …) were given. I am considering modeling this plate with triangular plate elements...
I have asked similar question earlier and one of answers was "Case A & B looks to be maximum variation in loading due to gusts at different times". Hope this helped.
IV
I forgot you use AutoCADLT and it doesn't support AutoLISP. You may try LT-Extender 2000 Plus
http://www.cadopolis.com/shareware/shareware_listing.asp?TheCategory=&TheSubcategory=&StartNo=260&TheKeywords=
Should wind load on purlins HSS10x4 welded to main roof trusses (see attachment) be calculated using factors for MWFRS or C&C? I thought for purlins, in this case since they are part of main wind force resisting system, should MWFRS factors used. In what part of ASCE 7 is this? Thanks IV
I have designed canopy spread footing using load combination 0.6D+W and 1.0 factor of safety for overturning and uplift but reviewer wants me to use FOS=1.5 It looks very conservative to me and I could not find this in IBC. However PIP STC01015 Structural Design Criteria Section 4.3.7.2 is very...
Thanks to all for your valuable inputs. You have already noticed I made a typo - ASD gives you LARGER bolts than LRFD not smaller. For example ASD load comb is 1,000# tension per bolt and LRFD 2,000#. 1/4” dia bolt w/ 2” embedment has allowable load 560# and ultimate load 2100#. Therefore using...
Catalogs for adhesive or mechanical anchor bolts usually give allowable and ultimate loads and their ratio is around 1:4. However ratio between nominal loads (using allowable stress design) and factored loads (using strength design) is less than 1:2. This means allowable stress design gives you...