  1. gusongjun

    Sanitary flow rate and Fixture unit method

    To bimr: Thanks for your reply. Problem is I don't know how many people will work in each building. What I know is building layout. So I know the amount of closets, sinks, showers and so on. Then, I converted fixture units counted into water discharged (all consumped water will be discharged...
  2. gusongjun

    Sanitary flow rate and Fixture unit method

    I am designing underground sanitary system in an industrial area. To calculate effluent rate, Fixture Unit method is used. Effluent to MH1 = 5.8 l/s MH2 =7.185 l/s MH5=2.032 l/s MH7=2.132 l/s Question 1: From Manhole 2 to Manhole 5, I add 5.8 l/s + 7.185 l/s = 12.995...
  3. gusongjun

    HDPE pipe elevation tolerance.

    To bimr The pipe is new installed in industrial area for waste water. Before installation, dewatering had been done to dry trench.
  4. gusongjun

    HDPE pipe elevation tolerance.

    There is 300 mm bedding sand for those pipes. Bedding sand shall be comptacted to 98% SPMDD. So I think 50 mm tolerance is not tight. But the contractor intalled pipes some where is out of tolerance. The worst place is 78 mm deviation. Gee, do you guys have meet same suitation? Thanks!
  5. gusongjun

    HDPE pipe elevation tolerance.

    To cvg Yes, I permitted 50 mm deviation of elevation for contractor. I don't know why they can't install pipe within the tolerance. These pipes are not big or heavy. Gee.
  6. gusongjun

    HDPE pipe elevation tolerance.

    Thanks. These pipes are 8" and 10". As built deviation is around 100 mm. Without any sepecial reason, I think 100 mm deviation is acceptable. Do you have any similar experience?
  7. gusongjun

    Why horizontal distance on Gravity Sewer Profiles?

    See below, Assume the distance manhole to manhole is 180 m, slope is 1.5%, so the actual length along the profile is SQRT(180^2+(180*1.5%)^2)=180.020 m. Do you think there is a big problem with 180 m and 180.020 m? Usually only horizontal distance is used.
  8. gusongjun

    HDPE pipe elevation tolerance.

    Hi, guys, I have some deep underground HDPE pipes, DR 9 and DR 11. I am wondering who know elevation(grade) deviation for these kind of pressured pipes. Many thanks for your kind consideration. Any reply is greatly appreciated. Best regards,
  9. gusongjun

    Surcharge Loading for Heavy Haul Road

    don't forget the factor of safety, compact load too.
  10. gusongjun

    Pipe Location

    I only saw on line installed on the top of pipe. Then those pipe were buried. I thought a lot portable equipments can detect those underground pipes. Usually burial depth shall be less than 3 to 4 meters.
  11. gusongjun

    Minimum Distance between vertical curves

    Horizontal curves usually connected by tangential straight lines. The length of tangential lines shall be not less than 4 times design speed. For example, design speed is 60 km/h, the minimum length of tangential line shall be 240 m. Regarding spacing vertical curves, I can’t remember any...
  12. gusongjun

    Manhole tolerance

    To cvg: Thank you! I don't mean tolerance of pipe invert grad and line. I want to what the tolerance for concrete manhole. I heard that tolerate for elevation is <=10 mm, elevation is <=10 mm as well.
  13. gusongjun

    Manhole tolerance

    Sorry. I might confuse you. For the tolerance, I mean as-built coordinates/elevation is not same designed coordinates/elevation. So the tolerance for this difference. Many thanks for your kind concern. Best regards,
  14. gusongjun

    Manhole tolerance

    Tolerance for offset.
  15. gusongjun

    Pinping test Vs backfilling

    to SNORGY Thanks for your reply.
  16. gusongjun

    Manhole tolerance

    Hi, Regarding manhole installation, does anybody know the tolerance? Thanks a lot!
  17. gusongjun

    Pinping test Vs backfilling

    to SNORGY and zdas04: Thanks for your replies. It is my fault. These pipes are buried in plant site. I am civil guy not piping/mechanical. Your responses are very helpful.
  18. gusongjun

    Pinping test Vs backfilling

    Thanks all replies. CSA 662-07 clause 8.1.7 Compressor and pump station piping designed in ASME B31.3 shall be pressure tested in accordance with the pressure-testing requirements of ASME B31.3. I checked the piping design specification, all pipes were designed based on ASME B31.1 and ASME...
  19. gusongjun

    Pinping test Vs backfilling

    Hi, I have some pipes buried underground. To improve schedule, I am wondering whether I can complete piping test after backfill accomplished. Thanks for your kind concern.
  20. gusongjun

    Footprint area of haul truck 797B

    cvg, thanks for your reply. I check the link that you gave. Under 'dimensions', I can't find the footprint areas of front tires or rear tires.