Hi simchuck,
In the case of a double pipe heat exchangers, you'll need two distinct equivalent diameters:
- for heat transfer : Deq = (Di^2 - do^2)/do.
- for pressure drop : Deq = Di - do.
I would mention that the correlated given here (sieder and tate) is valid only for turbulent...