You did not state the type of compressor, but gas turbine cooling is quite common and offers a relatively quick payback in certain geographical regions. Check out Turbo Refrigeration as one site. There are several methods of refrigerated cooling, so find out which is best for your application.
I have experienced pitting corrosion of nickel rupture disc protecting anhydrous ammonia pressure vessel. EDS lab test indicates high amounts of chlorine at the pits. The source of the chlorine is unknown at this time. No other elements of any amount are present. Would chlorine cause the...