Hi,I am a junior engineer tasked with designing a simple system.
The system consists of 6 H2 gas cylinders, stationed in 3 gas cabinets. 3 gas cylinders will be in use and the other 3 gas cylinders will be on standby. H2 gas is piped for use for the GCs in our QC Lab.
The gas cylinders will...
Hi Littleinch,
We are still in the process of obtaining the information as noted by TGS4.
Hi MJCronin,
Thank you so much for the advice.
My senior colleague has experience in this industry (ex-Linde) but is better versed for bulk oxygen systems. Our country only has standards for bulk...
Hi Littleinch,
Thank you so much for the detailed explanation.
My senior colleague actually asked this question, and he gave me some more details this morning.
He wanted to know if a Schedule 40 pipe is enough for a 6" pipe carrying O2 at 20 bar, above ground, and he would like to know the...