before You use mptemp second or third time use
mptemp
command. (blank, without any options) it will delete previous temperature table.
this error appears if You used for example
mptemp,1,100,200,300...
and for other material properties
mptemp,1,250,300,400
then while writing in temperature...
I have problem with contact modelling – too large penetration. Warning message say: „Convergence has been achieved in spite of large penetration. If this message is repeated frequently, we recommend either increasing penalty stiffness <FKN>, or enlarge penetration tolerance <FTOLN>”. Changing...