Thanks gents. I really appreciated your help!!!
I designed as total for conservative. I'm still holding a concern that the bottom part of pipe will buckle if they put a dummy support at the very bottom.
A flexi connection at the bottom would be best, as well as string lifting from the top. The...
Hi Guys
I got this question for a vertical pipe, hundreds meter deep for underground mine dewatering.
I'll need to work out the weight to support for the hanger design. No piping engineer to provide the load, unfortunately...
The total pipe weights about 5t and content weights 7t. vertically...
Hi Guys
I got this concern while doing the load combinations. Would like to get some hints.
The background is process structure using AS 4100, 1170, 3600...
In a lot of structural design criterias, there is always word saying "apply diffrential settlement load, and thermal load when required...