Thank guys.
Nbuska,
I agree, HDD is becoming very integrated and dense, but very cheap and poorly made.
But the fact is that most people are daily loosing valuable data on which you can not put a price tag. The isuue as you know is not the HDD, but the data specially on laptops and standalone...
itsmoked,
Thanks for your response.
A clean room I may not be able to afford immediately, but I hear we could make do with an 'clean box'. with insert for technician hands and tools.
problem is I do not have details of how this can be constructed, or where to obtain ready made ones.
I recently...
Want to start a business in data recovery and hard disk drive repair.
Anybody there knows what is required?
Software and Hardware requirements?
Also will appreciate any information on tools and equipment required for large scale recovery of components from old electronic boards.
How can I get my GSM handset to communicate with an application in my PC , say Ms-Access?
I want to be able to port one handset to my home pc. Message will pass thro the network from message originating handset to my handset connected to my home PC, and have these messages ported to Excell or...
k'byte
Thanks for your response, but what is a delay processor? What package does it come in, is there another name for such an equipment?
Say I have to go to an audio shop to buy it what shall I say to the dealer?
As to the number of people the hall can sit, 500-600 is possible.
Thanks k'byte
I missed it!
For designs, experience on previous works, i.e. man hours, leg work, and over heads are the inputs. in most cases this add-up to a percentage ranging between 2.5%-10% of the actual construction cost.
For a design job change orders are rarely expected for it is an indication that...
All Eng-Tips Audiophiles!
Please I need help to select a music amplifier audio system for a church hall.
However I am not sure how to size the power requirements for such a system considering the minimum permissible sound energy levels allowed for an auditorium.
Help is also needed on the...
Is 16M the budget limit?
Why not break down the entire project into different disciplines e.g. civil, mechanical, electrical,landscaping etc.
Having done that u may request for quotations from a minimum of three experienced contractors per discipline.
Then you compare their figures, take the...
We are on the same point, but differ on our approach to safety!
If u were installing this for others to operate and maintain
safety might be an issue which u may choose not to attend to.
But if you were to operate and maintain this system then safety will be an undelying principle right from...
from Ausphil:
"providing the minimum level is above the expected highest voltages seen on the system (be them overvoltages at power frequency, or switching or lightning impulses "
That's the determining factor, and it applies to the old and new hardware. In other words can the old cloth...
This looks like patching an old garment with new cloth,or better still putting new wine in old wine skins.
The concern here should be safety first!
What voltage levels do we expect when a fault occurs?
would it be okay if the whole systems fails becos the insulation level was not uniform...
Does this voltage drop occur only when the generator is loaded?
I will suggest you run the generator without any load connected, and observe if the voltage drops.