Good Morning to all,
i have a question. In a terminal where i'm working, we would to do the thickness control of the External FLoating Roof of an hold tank. We don't have drawings about that tank.
Does API provide acceptability percentages for the thickness test?
Thank you very much in advance...
Thank you to all for your replies, and, as you said, we think that is a problem of improper welder procedure.. cleaning weld seam, temperature maintenance during welding,moisture elimination etc etc..
I will inform you..
Thanks
Good afternoon to all,
i have a question for you. During maintanace operations of a tank, it's necessary to open a temporary door in the 1° shell course.
After 2 months that door was welded and regularly checked with RT and MT with with no defect, some toe cold cracking appeared in the...
Good evening sir,
if the construction company fails in the opening of a nozzle in a roof so they must close the hole, what's the procedure to follow?
Re-Welding, 100 % RX.....ETC ETC
What does API recommend in a similar situation?
regards
Good Evening sirs,
what are the acceptance criteria for a tank vent?
During the construction, perhaps for a incorrect procedure welding of a stair support, we have suffered this distorsion.
thanks
regards
Thank You very Much CarlB....i was right about the incorrect procedure. I'm working in tanks constuction but i'm a civil engineer so i have some knowledge about it.
regards
Hi guys..help me To understand chapter 7.3.6.5.API 650 First of all i think that this is a duty of The purchaser. Please confirm me.
Then, is 460mm/h The filling rate???Can You explain me The meaning of this value? I think It' s To much low But i m sure i m Not understanding.
Thanks
First of all thank you for your answers but beyond the usefulness of using this product i was curious to know if the application procedure was correct which is to pour the emulsion directly on the sand bed....for me it's strange because the result was a black colored sand not a bed of asphalt as...
Good Evening everyone
i have a technical question about the foundation.
Where i'm working the client is using a kind of bitumen emulsion on the sand as final layer. In the civil drawing i read "50 asphaltic sand" as final layer. From my point of view the procedure of the client is not correct...
Good Evening to all
i'd like to have a clarification.
Does API650 provide that for the welding annular-shell you have to start from the inside of the tank and not from the external?
thank you
regards