  1. stopsunset

    MTBF Startup Failures

    I would like feedback on the subject matter of MTBF. Do you account for failures related to startup when calculating MTBF?
  2. stopsunset

    PWHT of Monel 400

    Thank you Lee
  3. stopsunset

    PWHT of Monel 400

    Can anyone give me any insight into the Brinell Hardness requirements for Monel 400 after PWHT for pipe? Is it in the range of 160-185 BHN? I also can not find any information regarding at what hardness levels does Monel 400 become susceptible to cracking. I have seen some documentation...
  4. stopsunset

    Inspecting stormwater sumps

    thank you all for your insight.
  5. stopsunset

    Inspecting stormwater sumps

    stormwater containment sump would be a below grade, reinforced concrete sump with a submersible pump used to pump out stormwater. Typcal dimensions are 10ft wide by 10 ft deep.
  6. stopsunset

    Inspecting stormwater sumps

    Are there any industry codes for inspecting stormwater contaniment sumps? Any help would be apreciated.
  7. stopsunset

    ASME OR API Code for Inspecting Sumps

    Are there any industry codes for inspecting stormwater contaniment sumps? Any help would be apreciated.
  8. stopsunset

    SA-182 F316L and F316

    Thanks for the insight.
  9. stopsunset

    SA-182 F316L and F316

    Can anyone explain why the allowable stresses for F316 are higher than F316L in SA-182? It appears that above 850'F, 316L is not suitable wheras 316 has allowable stress up to 1500'F.Other than the low carbon content in the L grade, I see no difference in the composition.
  10. stopsunset

    Coppercoat in HF Alklations units

    I've seen that a copper based thread lubricant is not recommended for use in HF alkylation units, rather a Nickel base anti seize compound is recommended. Why is that? I've heard that for marine applications to prevent a galvanic cell from forming but not HF units.Thanks
  11. stopsunset

    Coppercoat in HF Alklations units

    I've seen that a copper based thread lubricant is not recommended for use in HF alkylation units, rather a Nickel base anti seize compound is recommended. Why is that? I've heard that for marine applications to prevent a galvanic cell from forming but not HF units.Thanks
  12. stopsunset

    Coppercoat in HF Alklations units

    I've seen that a copper based thread lubricant is not recommended for use in HF alkylation units, rather a Nickel base anti seize compound is recommended. Why is that? I've heard that for marine applications to prevent a galvanic cell from forming but not HF units.Thanks
  13. stopsunset

    Causes of pump casing damage??

    I agree....it appears to be corrosion/errosion.You may also want to consider a protective coating such as Belzona. http://www.belzona.com
  14. stopsunset

    API versus ANSI centrifugal pump

    The API standard is the most comprehensive engineering document with regards to safety and pump reliability. It was designed specifically for refinery applications whereas ANSI was developed for the chemical industry. The attention given to design detail(nozzle loading,torsional/lateral...
  15. stopsunset

    Boron Coating on Centrifugal Slurry Pump

    I have experience with Boron diffusion.If I understand the process correctly, it's not really a coating becuase the the boron actually diffuses into the metal(approx. 80 mils)rather than puddling on top of it. We modifies our FCC slurry pumps in 2000 by using this process on the wetted parts.We...