Lvl beam was cut roughly 1-1/4 inches to short. The LVL beam runs perpendicular to a steel beam and is attached to the steel beam via a ledger board. The LVL beam run about 8 feet long and connected to the sub floor with the appropriate engineered nails. One side of the LVL is attached to...