It seems that Ea= 0.6eV is a commonly accepted reference value.
I have also found a relation showing the acceleration due to RH and it could be another acceleration factor in my tests.
A=t_test/t_opearting=(RH_test/RH_opeating)^3* <Arrhenius equation>
Where:
RH_test= RH during test
RH_perating=...
Hello and thank you All for feedbacks.
Actually, I was not looking for theoretical, school or Wikipedia's material but rather something more operating and real experience-based.
I got plenty of materials from Internet but I was asking real field experience and help.
We experienced failure in...
Hi,
I am struggling with life prevision of bare Printed Circuit Board (PCB).
The approach is to submit a bunch of PCBs to climate chamber accelerated life 885°C/85%) for a certain amount of time.
The problem then is the correlation between such accelerated life time to teh standard/specs...