    Liquid psv line sizing

    Use rho v2 max 50,000 kg/m3 . m/sec for PSV inlet line and rho v2 max 25,000 kg/m3 . m/sec for PSV outlet line.
  2. skindeep0297

    Gas Dehydration Unit

    Hi all, I have a question about a gas dehydration unit with glycol solvent. I need to know the TEG Flow Rate and Purity for the following gas data: 1) Gas Flow 300 MMSCFD 2) Gas MW 21.73 3) Gas Temperature 37°C 4) Gas Pressure 53.8 barg 5) Gas Water Content 18 lb/MMscf (not saturated...
  3. skindeep0297

    Compressor-Polytropic and Isentropic Efficiency

    See attached http://files.engineering.com/getfile.aspx?folder=64d3af76-9084-44b7-944d-a4a8fe3c8f04&file=Conversion.docx
  4. skindeep0297

    Lines for H2

    Usually for a gas line the maximum velocity in terms of dv2 is 6000 kg/m3 . m/sec
  5. skindeep0297

    Vacuum Deaerator

    Tray to see the McGraw-Hill: Working Guide to Process Equipment Regards