Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations JAE on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by sinhock

  1. sinhock

    Restriction Orifice sized but choke

    thank you hacksaw. good to know the process downstream press dictates the RO downstream press. jc
  2. sinhock

    Restriction Orifice sized but choke

    Thank you Pierreick, Latexman and LittleInch for feedback. The RO selected has a thickness of 0.125" and thank you for the advise. jess
  3. sinhock

    Restriction Orifice sized but choke

    I've selected a 2" Restriction Orifice RO bore size 0.54" with process condition P1=790kPag, P2=110kPag, Q=18350 Sm3/d, T=15C on Utility Air. The sizing tells me I have critical dP=418 kPa meaning my predicted P2=372kPag. Is it true even though the RO is at choke flow and can only handle press...

Part and Inventory Search

Back
Top