  1. SHA4225

    Seal less Mag drive pumps

    Thanks Pumpsonly for your reply... Me-can-ikal-ly Stable
  2. SHA4225

    Seal less Mag drive pumps

    Thanks ash9144 and bimr for your replies... they are sealless pumps, & requirement for most of the pumps is dual containment. anyways, i havent had much experience with flowserv, but i will check if they can comply... thanks again for your help Me-can-ikal-ly Stable
  3. SHA4225

    Seal less Mag drive pumps

    i saw the detail of the Klaus... Thanks .... Vendor is Flowserv... i wanted to ask that if vapor pressure is low, and there is no chance of vapors, can the vapor leak detection requirement be omitted ? or shud it be considered for any possible fumes from the toxic service ? Me-can-ikal-ly...
  4. SHA4225

    Seal less Mag drive pumps

    Hi all, I have a query regarding Magnetic drive seal less pumps... Client's requirement is dual containment with liquid & vapor leak detection sensors. Vendor cant provide vapor leak detection in secondary housing, & suggests that bearing housing will act as secondary housing.... Service is...