Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Saralex

  1. Saralex

    Circular earth retention wall design methods

    Contractor is responsible for design of temporary ERS for a launching and receiving shaft for a sewer tunnel. Inside diameter 35 feet and excavation depth 42 feet. Contractor proposing a secant pile wall with 2 foot diameter auger cast piles, every other pile steel reinforced. His design...