Recent content by samuel.warner

  1. samuel.warner

    Air requirments for pneumatic filling

    Thank you all for the responses. I guess my original approach was right just not the execution as you all have pointed out.
  2. samuel.warner

    Air requirments for pneumatic filling

    180 gpm equals 24.1 acfm, which was my initial thought assuming the acfm air flow would be the same as the liquid outflow. I converted to scfm because that's what was asked of me to find. seems too low to me though for this to be correct.
  3. samuel.warner

    Air requirments for pneumatic filling

    Hi, I am trying to calculate the SCFM for a compressor used for pneumatic filling of chemical tanks. • I know that there is 15 psi of losses in the line from the truck to the tank, the max pressure is 25-30 psi and that the desired flowrate of the chemical is 180 gpm. I initially thought the...