Assume a you need to model a cable connected to the face of free standing column and being pulled laterally.
1- If you don't use the insertion point: The analysis won't result in any torsion to the member, because the cable will be considered connected to the centroid of the column.
2- If you...
Thanks JAE
Referring back to EN 1991-1-4:2005, I found that they are addressing the free-standing canopies.
However, they are only providing the pressure coefficients for "monopitch" and "duopitch" but for curved roof they include it only for enclosed structures.
I think I will have to adopt...
Hi,
For car sheds similar to these:
http://www.polycongulf.com/Uploads/Product/26_Car-shed.jpg
http://upload.ecvv.com/upload/Product/20111/China_Car_Shed_Polycarbonate_Sheet20111211039457.jpg
There is possibility of having the wind load acting on the underside of the roof, causing uplift...
In Appendix D of "Wind loading structures", 2nd edition, John Holmes
It contains a list of basic wind speeds for several countries around the world. However, it doesn't contain Ghana, but it has values for Mauritania and Morocco.
Good luck
Hi loki3000
Thanks for the reply
I'm a structural engineer, and recently have learned Ansys WB which I'm looking forward to use it as extra verification whenever it's needed.
For NL, I found that ANSYS will accept a NL material if it has as minimum as Tangent modulus and yield strength.
Do you...
STAAD pro has one major advantage that is the very user friendly interface and you can learn much of the software in short period. Also you can easily model your structure there either through the GUI or by defining members nodes coordinates then connect them through the code editor, first you...
Very interesting and wish you all the best
Yesterday I was searching for some sources for structural stel material properties and found myself in this Biomesh web site
http://www.biomesh.org/
I though of sharing in case you haven't been there before
Good luck
I remember a colleague who told me about a ready-mix concrete slump test with slump of 150 mm (acceptable and used for a multi-million project) and there were no shrinkage cracks.
I assume that very high workability was due to admixtures rather than higher w/c ratio! Or maybe balancing between...
Hi
What are the minimum required material properties to perform static structural steel linear and non-linear analysis?
I have used the data available in Ansys WB library for structural steel and just made some modifications on yielding strengths. I'm getting reasonable results when using NL...