  1. R

    Gas turbine tripped with "LONG DC RUN TIME"

    Hi, In SGT600 gas turbines, there are no separate AC and DC lubrication pumps, instead the pumps have AC and DC feeds. AC feeds and it's loop were faultless.
  2. R

    Gas turbine tripped with "LONG DC RUN TIME"

    Hi every body, the GT10B2(SGT600) Gas turbine's rectifier 440 vdc has been failed due to high temp. Of inside and then Gas turbine tripped due to a "LONG DC RUN TIME" alarm despite of the presence of gas turbine's AC power. In this situation, lub oil pumps are working with batteries for 10...