Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by PaulLDE

  1. PaulLDE

    Sewage force main freeze potential

    The existing condition is a 4 inch dia. ductile iron sanitary sewage force main with 20" to 24" of cover ( earth and pavement). Minimal cover occurs along a length of 60 feet in the middle of a 500 foot long force main. Standard cover to be below frost lines in our area (New Jersey)...